Accessibility Information

Users of assistive technologies such as screen readers should use the following link to activate Accessibility Mode before continuing: Learn more and Activate accessibility mode.

Y--Utah Data Center

Solicitation Number: W912DR-10-R-0015
Agency: Department of the Army
Office: U.S. Army Corps of Engineers
Location: USACE District, Baltimore
  • Print
:
W912DR-10-R-0015
:
Award
:
September 24, 2010
:
W912DR-10-C-0015
:
$1,198,950,000.00
:
BALFOUR BEATTY/DPR/BIG-D, A JOINT VENTURE
:
961604365
:
404 W 400 S
SALT LAKE CITY, Utah 84101-1108
United States
:
Added: Dec 18, 2009 10:20 am Modified: Feb 03, 2010 1:23 pmTrack Changes
The proposed procurement is Unrestricted. NAICS Code: 236220, Size Standard is $33,500,000.00. This procurement is being advertised as a Two Phase Request for Proposal (RFP). The magnitude of construction is greater than $500,000,000. The completion period is expected to be approximately 1,100 calendar days from notice to proceed. The bonding requirements for this solicitation has been set at $750,000,000.

The project consists of the design and construction of a Tier III, 65 MW technical data center, located on Camp Williams, Utah. Basic ancillary supporting design and construction services include, but are not limited to: providing basic utility infrastructure, electrical service (primary power and temporary construction power), water, sewer, and gas. The facility itself will consist of approximately 1M SF of facility, of which 100K SF will be mission critical data center space with raised flooring and 900K SF of technical support and administrative space. Anci llary supporting facilities include, but are not limited to: water treatment facilities (pre and post), vehicle inspection facility, interim visitor control center, perimeter site security measures, fuel storage, water storage, chiller plant, fire suppression systems and 100% electrical generator and UPS back up capacity. The schedule will be very aggressive.

The project will be designed and constructed in accordance with the Uniform Federal Accessibility Standards (UFAS)/Americans with Disabilities Act (ADA) Accessibility Guidelines, and Antiterrorism Force Protection (ATFP) standards. Unified Facilities Criteria (UFC) to be an integral part of design consideration.

Please consult the list of document viewers if you cannot open a file.

Utah Data Center - DRAFT RFP

Sensitive/Secure Package:
Yes
Label:
Utah Data Center - DRAFT RFP
Posted Date:
December 18, 2009
Login Required

10-R-0015

Sensitive/Secure Package:
Yes
Label:
10-R-0015
Posted Date:
January 25, 2010
Login Required

Amendment 1

Type:
Mod/Amendment
Posted Date:
February 3, 2010
Description: Amendment 1

Amendment 2

Sensitive/Secure Package:
Yes
Label:
Amendment 2
Posted Date:
February 17, 2010
Login Required
:
US Army Corps of Engineers, Baltimore, 10 South Howard Street, Baltimore, MD 21203
:
UTAH DATA CENTER
Camp Williams, Utah
United States
:
Carlen Capenos,
Contract Specialist
Phone: 410-854-0739